An Official publication of The Asian Congress of Neurological Surgeons (AsianCNS)

Search Article
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Advertise Subscribe Contacts Login  Facebook Tweeter
  Users Online: 335 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size  
 
ORIGINAL ARTICLE
Ahead of Print

Experimental evaluation of the risk of distal embolization during endovascular clot retrieval using various techniques


1 Neuroendovascular Therapy Center, Aichi Medical University, Nagakute, Aichi, Japan
2 Neuroendovascular Therapy Center, Aichi Medical University; Department of Neurosurgery, Aichi Medical University, Nagakute, Aichi, Japan

Correspondence Address:
Tomotaka Ohshima,
1-1 Yazakokarimata, Nagakute, Aichi 480-1195
Japan
Login to access the Email id

Source of Support: None, Conflict of Interest: None

DOI: 10.4103/ajns.AJNS_237_20

Background: This study was conducted to evaluate various devices and techniques for endovascular thrombectomy that can reduce the risk of intraprocedural distal embolism in a preliminary in vitro setting with different types of thrombi. Materials and Methods: Endovascular clot retrieval was performed in a vascular model with collateral circulation. White and red thrombi were prepared using whole blood collected from a pig. A Direct Aspiration First Pass Technique (ADAPT), simple stentretrieving with and without proximal flow arrest by a guiding balloon (SR [B+] and SR [B±]), the AspirationRetriever Technique for Stroke (ARTS), and A stentretrieving into an Aspiration catheter with Proximal balloon (ASAP) were performed three times, respectively. The saline samples that were collected at the distal side during each procedure were examined using a particle counter. The particles were counted and categorized into three groups based on size (100 μm). Results: SR (B−) and SR (B+) could not achieve complete retrieval of the clot, especially using the white thrombus. ASAP was the only method that was able to retrieve the clots in all attempts. In both clot types, SR (B−), SR (B+), and ARTS, which involved a temporary flow restoration through stent deployment, demonstrated the migration of a greater number of particles measuring >100 μm in size than that shown by ADAPT and ASAP. Conclusions: ASAP was the safest method in terms of intraprocedural clot migration among the five methods evaluated in this study. Temporary flow restoration through stent deployment may affect the dangerous distal clot migration.


Print this article
Search
 Back
 
  Search Pubmed for
 
    -  Ohshima T
    -  Miyachi S
 Citation Manager
 Article Access Statistics
 Reader Comments
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed13    
    PDF Downloaded1    

Recommend this journal