Figure 1: Dual microcatheter balloon occlusion coiling technique. (a) Step 1: Placement of dual-lumen balloon (balloon test occlusion can be completed, if desired). (b) Step 2: Placement of microcatheter at distal occlusion limit (balloon deflated). (c) Step 3: Placement of distal defining coil (not detached, balloon inflated). (d) Step 4: Coiling proximally through dual-lumen balloon microcatheter (multiple coils detached). (e) Step 5: Deflate balloon. If no movement of coil mass, then distal defining coil is detached

Figure 1: Dual microcatheter balloon occlusion coiling technique. (a) Step 1: Placement of dual-lumen balloon (balloon test occlusion can be completed, if desired). (b) Step 2: Placement of microcatheter at distal occlusion limit (balloon deflated). (c) Step 3: Placement of distal defining coil (not detached, balloon inflated). (d) Step 4: Coiling proximally through dual-lumen balloon microcatheter (multiple coils detached). (e) Step 5: Deflate balloon. If no movement of coil mass, then distal defining coil is detached